AKAI
ALESIS
CLAVIA
E-MU
ENSONIQ
KORG
KURZWEIL
ROLAND
WALDORF
YAMAHA
HARDWARE
AARDVARK
ECHO
EDIROL
FATAR
MIDIMAN
TERRATEC
SOFTWARE
BITHEADZ
CAKEWALK
CODA
EMAGIC
PROPELLERHEAD
SIBELIUS
SONIC FOUNDRY
STEINBERG
|
Its a Fact
The AE-7000 is an interface unit for use with digital devices conforming to 4-route (8-channel) AES/EBU standards-including
ProToolsTM and other high-end digital recording equipment.
The AE-7000 communicates with AES/EBU equipment using Roland´s R-BUS technology, found on select
V-Mixers and the VSR-880 Digital Studio Recorder.
Features include:
- AES/EBU interface box which converts standard digital signals (up to four routes/eight channels) to R-BUS signals for use with select V-Mixers and the VSR-880
- Converts 8-channel digital output from R-BUS ports to AES/EBU standard digital signals
- 24-bit I/O for pristine sound quality
| Connecting to the VM7000 Mixer
|
Note: To connect the VM-7200/7100 and the AE-7000 via R-BUS, a VM-24E I/O Expansion Board (sold separately) must be installed in the processor.
- With the power off to all devices, connect the VM-7200/7100 to the AE-7000 with the R-BUS cable provided with AE-7000.
- Turn the power on the AE-7000 first, then the VM-7200/7100 processor. Wait for the VM-7200/7100 control status to change to green, then turn on the VM-C7200/C7100 console.
- Press CLOCK SOURCE on the AE-7000 to "R-BUS" to set the sampling clock.
Set-up the VM-7000 as follows:
- Hold down SHIFT and press PROJECT on the VM-C7200/C7100 console.
- Press the DOWN cursor to select the second row of the SYSTEM MENU.
- Press F1 [DIGITAL I/O].
- Press the DOWN cursor to select "WORD CLOCK SOURCE."
- Use the V1 knob to select "INTERNAL."
- Press F1 [SET] to confirm the setting.
| Connecting to the VM3100Pro
|
Use the following procedure to set-up the AE-7000 for use with the VM-3100Pro:
- With the power off to all devices, connect the VM-3100Pro to the AE-7000 with the R-BUS cable.
- Turn on the AE-7000, then the VM-3100Pro.
- Press CLOCK SOURCE on the AE-7000 to select "R-BUS" as the sampling clock.
Set-up the VM-3100Pro as follows:
- Press the SYSTEM/CONTRAST button.
- Use the TIME/VALUE dial to select "INTERNAL."
- Press LEVEL METER to exit.
| Connecting to the VSR880
|
Use the following procedure to set-up the VSR-880 for us with the AE-7000:
- With the power off to all devices, connect the VSR-880 to the AE-7000 with the R-BUS cable.
- Turn on the AE-7000, then the VSR-880.
- Press CLOCK SOURCE on the AE-7000 to select "R-BUS" as the sampling clock.
Set-up the VSR-880 as follows:
- Hold down SHIFT and press SYSTEM. "SYS SYSTEM PRM?" will appear in the display.
- Press ENT/YES.
- Use the TIME/VALUE dial to select "SYS MasterClk=INT."
- Press ENT/YES to confirm the setting.
- Press PLAY/DISPLAY to exit.
|