The ADA-7000 is an 8-channel, 24-bit A/D-D/A converter for use with select
Roland R-Bus compatible V-Mixers and the VSR-880 Digital Studio Recorder.
Features include:
- Analog inputs: 8 balanced XLR jacks (with phantom power supply) and 8 1/4-inch jacks
- Analog outputs: 8 balanced XLR jacks and 8 RCA jacks
- Programmable gain control using R-BUS signal from VM-7000 mixer series
- 96kHz compatibility for use with future Roland products
- Convenient 2U rack space design
| Connecting to the VM3100Pro
|
Use the following procedure to set-up the ADA-7000 for use with the VM-3100Pro:
- Power off all devices.
- Connect the VM-3100Pro to the ADA-7000 with the R-Bus cable provided with the ADA-7000.
- Turn on the ADA-7000, then the VM-3100Pro.
- Press CLOCK SOURCE on the ADA-7000 to select "R-Bus" as the sampling clock.
Set up the VM-3100Pro as follows:
- Press the SYSTEM/CONTRAST button.
- Rotate the TIME/VALUE dial to select "INTERNAL."
- Press LEVEL METER to exit.
| Connecting to the VSR880 |
Use the following procedure to set-up the VSR-880 for use with the ADA-7000:
- With the power off to all devices, connect the VSR-880 to the ADA-7000 with the R-Bus cable.
- Turn on the ADA-7000, then the VSR-880.
- Press CLOCK SOURCE on the ADA-7000 to select "R-Bus" as the sampling clock.
Set up the VSR-880 as follows:
- Hold down SHIFT and press SYSTEM. "SYS SYSTEM PRM?" will appear in the display.
- Press ENT/YES.
- Use the TIME/VALUE dial to select "SYS MasterClk=INT."
- Press ENT/YES to confirm the setting.
- Press PLAY/DISPLAY to exit.
| Connecting to the VM7000 Mixer |
Note: To connect the VM-7200/7100 and the ADA-7000 via R-Bus, a VM-24E I/O Expansion Board (sold separately) must be installed in the processor.
- With the power off to all devices, connect the VM-7200/7100 to the ADA-7000 with the R-Bus cable provided with ADA-7000.
- Turn the power on the ADA-7000 first, then the VM-7200/7100 processor. Wait for the VM-7200/VM-7100 control status to change to green, then turn on the VM-C7200/C7100 console.
- Press CLOCK SOURCE on the ADA-7000 to "R-Bus" to set the sampling clock.
Set up the VM-7000 as follows:
- Hold down SHIFT and press PROJECT on the VM-C7200/C7100 console.
- Press the DOWN cursor to select the second row of the SYSTEM MENU.
- Press F1 [DIGITAL I/O].
- Press the DOWN cursor to select "WORD CLOCK SOURCE."
- Use the V1 knob to select "INTERNAL" .
- Press F1 [SET] to confirm the setting.
|
Controlling the ADA7000 remotely from the VM7000 Mixer
|
Use the following procedure for controlling the gain and phantom power settings from the VM-7000:
- Press MULTI-IN 1-24 in the "SECTION" block.
- Press PREAMP GAIN in the "PARAM VIEW."
- Move the fader to adjust the inputs gain setting from 4 dB to + 64 dB.
- Press the corresponding F1, F2, F3, F4, F5 or F6 button to turn phantom power on or off.
|